10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator

Type: Power
Certification: ISO9001:2000, CCC, CE
Form: All- packaged Type

Products Details

Basic Info.

Model NO.
Static Var Generator 04
Operation Voltage
Low Voltage
Size
425*88*380 mm
Application Range
Power Factor Correction
Shell Material
Aluminum-Zinc Coated Case
Shell Protection Grade
IP30
Brand
Huakun
Mounting Type
Wall Mounted/Rack Mounted
Power Grid Structure
3p3w/3p4w
Noise Level
<65dB
Harmonic Compensation Range
2~50th Harmonic Order
Harmonic Compensation Efficienc
> 97%
Usage
Harmonic Correciton ,Reactive Var Compensation
Transport Package
Wooden Box
Specification
575*110*530MM
Trademark
Huakun
Origin
Shanghai, China
HS Code
8543709990
Production Capacity
20000PCS/Year

Packaging & Delivery

Package Size
15.00cm * 30.00cm * 10.00cm
Package Gross Weight
15.000kg

Product Description

10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var CompensatorStatic Var Generator (SVG) is a product aimed for Power Factor Correction, Voltage Regulation along with Three-phase Balancing Function. SHHKK-SVG can do bi-directional power factor correction, PF from 1.0 inductive to 1.0 capacitive. Benefiting from inverter technology, SVG compensation is stepless, which means SVG output shall match the system reactive power, no over-compensation or under compensation. For single module, SVG capacity ranges from 35kvar to 150kvar. For cabinet system, it's unlimited parallel design .
Compared with the traditional capacitor bank, SVG has the advantages of fast response and high
compensation accuracy without under-compensation or over-compensation problems.
Δ  Improved power factor PF ≥ 0.99
Δ  Compensated inductive or capacitive reactive
Δ  Unaffected by harmonics

10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var CompensatorHKK-SVG static var generator is a bridge converter composed of fully controlled power electronic devices for dynamic reactive compensation. The basic principle is that the load current is detected in real time by the external current transformer (CT), and the reactive content of load current is extracted by the internal DSP computing. Finally, the instruction value is calculated to control the PWM signal generator to send the control signal to the internal IGBT, so that the inverter can produce the reactive compensation current to meet the requirement, and finally realize the dynamic reactive compensation.
10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator
System parameters
Rated input wire voltage
3 8 0 V(-1 5%~+2 0%)
Grid frequency
5 0 / 6 0 H z ( r a n g e : 4 5 H z~6 2 H z)
Number of parallel machines
1 ~ 1 0 s e t s
Overall efficiency
≥9 7%
Grid structure
T h r e e - p h a s e t h r e e - w i r e / t h r e e - p h a s e f o u r - w i r e
Current transformer
1 5 0/5~1 0 0 0 0/5
Circuit topology
T r i - l e v e l
 P e r f o r m a n c e   i n d e x
Response time
<1 5 m s
Scope of compensation
F r o m - 1 t o 1 , c a p a c i t i v e  a n d  i n d u c t i v e  c o n t i n u i t y  i s  a d j u s t a b l e
Cooling mode
I n t e l l i g e n t   a i r   c o o l i n g
Noise index
<5 6 d B
10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator10kvar 15kvar 20kvar 25kvar Static Var Generator Static Var Compensator

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours